TLM
Sofima

2 MPa (20 bar)
Port sizes: 3/8” ÷ 1” 1/2
Flow rates: 4  ÷  600 l/min
Technical data
Max. working pressure: 2 MPa (20 bar)
Max. test pressure: 4 MPa (40 bar)
Bursting pressure: 6 MPa (60 bar)
Fatigue test: 0 ÷ 1 MPa (10 bar) / 300.000 cycles
Filter element collapse pressure:
Standard: ∆p 300 kPa (3 bar) all types
Working temperature: -25 ÷ +110°C
Materials
Head: aluminium
Bowl: painted steel
Seals: standard NBR (on request FKM)
Compatibility (ISO 2943)
Full with fluids: HH-HL-HM-HV-HTG (according to ISO 6743/4). 
For fluids different than the above mentioned, please contact our Sales Department.
All tests performed according to the following standards: 

  • ISO 2941: Element collapse resistance test
  • ISO 2942: Production integrity test
  • ISO 2943: Fluids compatibility
  • ISO 3723: End load test method
  • ISO 3724: Flow fatigue resistance method
  • ISO 3968: Pressure drop versus flow rate
  • ISO 16889: Multipass test. 
Filter Code
TLM 019 - TLM 055 - TLM 115 - TLM 150

Гидравлические системы и компоненты